117
70.1 Barcode
70.1 ESC+BL~ESC+d UPC-A Barcode
(Selection of HRI)
ESC+BL
~ ESC+d
Hexadecimal
code
ESC
BL~
Parameter
<1B>
16
<42>
16
<4C>
16
~
Character type
abbcccn~n~<d>n~n
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The parameter preset will be invalid.
Valid range between item
The parameter preset will be invalid.
[Function]
Adjusting the barcode character height of the first and the last digits to the same as that of the guide bar.
[Format]
<BL>abbcccn~n ~ <d>n~n
●Parameter
a[Barcode symbology] = H : UPC-A ('H' fixed)
b[Narrow bar width] = Valid range : 01 to 36 dots
c[Height of barcode] = Valid range : 001 to 999 dots
n[Print data] = Data : 11 fixed digits
d[Character type specification] = OA
OB
XU
XS
XM
XB
XL
U
S
M
WB
WL
n[Print data] = HRI data : 12 fixed digits
[Coding Example] Barcode symbology : UPC-A Narrow bar width : 02 Height of barcode : 120
Barcode data : 01234567890 Character type : XS HRI data : 01234567890
<A>
<H>100<V>100<BL>H0212001234567890
<XS>01234567890
<Q>2
<Z>
UPC-A Barcode
(Selection of HRI)