118
[Notes]
1. This command supports UPC-A only. When setting [Barcode symbology] to the value other than ‘H’, command error will
occur.
2. HRI requires the following terms.
For 8 dots/mm, [02] and [03] would be a proper value of narrow bar width.
For 12 dots/mm, [03] and [04] would be a proper value of narrow bar width.
For 24 dots/mm, [06], [07] and [08] would be a proper value of narrow bar width.
3. Please set the correct calculation for the check digit that is the 12th digit of the HRI data by using modulus10.
4. Settings for guide bar, HRI and Ratio are as follows.
5. The operation when invalid parameters are specified is not guaranteed.
6. HRI will not be printed when barcode is an error for barcode with HRI.
7. The height of the character barcode is the same when printing UPC-A by using barcode command <D> followed by
<character type> data, however, the height of the first digit and the last digit of the character code will be the same as the
guide bar when printing with UPC-A barcode command <BL> followed by <character type> data. Also, HRI can be printed
from below the first digit to the last digit because the height of the barcode is shorter when printing UPC-A by using barcode
command <D> followed by <character type> data, however, the printable area of HRI will be narrower compared to the
barcode command <d> followed by <character type> data when printing UPC-A with UPC-A barcode command <BL>
followed by <character type> data because the first digit and the last digit's height is longer.
Print result of UPC-A of barcode command <D> Print result of UPC-A of UPC-A barcode command <BL>
followed by <character type> data followed by <character type> data