78
51.1 ESC+k1(k2) Call of Vertical Writing
External Character
<6B>
16
<31>
16
(<6B>
16
<32>
16
)
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Invoking vertical writing external character registered in the printer memory to print.
[Format]
<k1>ab~b
<k2>ab~b
●Parameter
a [External character specification mode] = H : Hexadecimal character
B : Binary code
I : Smoothing function by Hexadecimal character
C : Smoothing function by Binary code
J : Highlight function by Hexadecimal character
D : Highlight function by Binary code
K : Smoothing and highlight functions by Hexadecimal character
E : Smoothing and highlight functions by Binary code
b [Registration code] = H,I,J,K : “8021”~“807F”
B,C,D,E : 8021H~807FH
[Coding Example] Recall 16x16 external characters, registration data by HEX characters of GB18030
<A>
<T1>H21
00FF ・・・・・・・・・・FF00
<Z>
<A>
<V>100<H>200<k1>H8021
<Q>2
<Z>
[Notes]
1. If print error occurs, register again.
2. Please specify the slot of the memory to be recalled.
However, data in the internal memory will be recalled when <CC> command is not yet sent after the printer power on.