142
[Coding Example2] Error correction level: 7%, Size of one side of cell: 04
Mixed specification of Manual setup (Data setup mode)
In Manual setup, you can proceed specifying data in specified input mode (Numeric, Alphanumeric, Kanji,
Binary) in a row.
<A>
<V>100<H>200
<2D32>,L,04,0
<DS>3,サトー
<DN>0010,0123456789
<DS>1,123
<Q>1
<Z>
[Note 3]
Please specify the data part after the parameter part. Also, specify the data part after the data part continuously. When this
fails, printing
may not be correct.
Micro QR code data size table
L
(Error correction
only)
[Coding Example 3] Error correction level: 7%, size of a side: 05
data setting mode: manual setting, combine mode: normal, printed in version M4
<A>
<V>100<H>200
<2D32>,L,05,0,0
<QV>4
<DS>1,012345
<DN>0004,6789
<Q>1
<Z>
[Note 4]
1. Specify the <QV> command in between <2Dxx> and <DN>/<DS>.
2. When the parameter error occurs, it will be treated as no specification.
3. The parameter error will not occur in the range of 00~40. (Please specify the value in the range supported in the model)
Setting range (Micro QR): 00 to 04
4. The command error occurs and the Micro QR code will not be printed when data exceeded the size limit of the specified
version data size.