235
[Valid Commands]
In general, this command is used for [Registration No.] only. Specification of window height and width will control the movement
with Vertical Print Position <V> and Horizontal Print Position <H> at the time of calling. For the movement at the time of calling, if
registered area is exceeding printable area, the portion outside of the printable area will not be printed.
The following are the brief operation.
1) Normal (To register)
<A>
<V>100<H>100<P>2<L>0202
<XB>0ABCD
<V>60<H>60
<FW>0808V800H400
<V>320<H>60
<FW>04H400
<CC>1
<&S>,1
<Z>
2) When the print is specified after the command <&S>
<A>
<V>100<H>100<P>2<L>0202
<XB>0ABCD
<V>60<H>60
<FW>0808V800H400
<V>320<H>60
<FW>04H400
<CC>1
<&S>,1
<V>200<H>100<OB>12345
<Z>
Anything specified prior to the command
<&S> will be registered as form overlay.
ABCD