295
8. For filter values used in SSCC96 /SGTIN96, please refer to the table below.
Filter value standard table
Filter value
SSCC96
SGTIN96
0
All Others
All Others
1
Reserved
Point of Sale (POS) Trade Item
2
Full Case for Transport
Full Case for Transport
3
Reserved
Reserved
4
Reserved
Inner Pack Trade Item Grouping for
Handling
5
Reserved
Reserved
6
Unit Load
Unit Load
7
Reserved
Unit inside Trade Item or component inside
a product not intended for individual sale
9. SSCC96 code conversion
This function is used to generate a code according to the SSCC96 standard when a company prefix, serial reference,
and filter value are applied. It is possible to use with Gen2.
The command/parameter configuration is explained with the below values. These are all decimal numbers.
Company prefix: 4011661 (7 digits)
Serial reference: 3000000001 (10 digits)
Filter value: 0 (Select the filter value from the filter value standard table described earlier. In this example, the filter
value is 0 from "All Others")
The total digit number of company prefix and serial reference needs to be 17 under the standard, and it is not possible
to change. Of these 17 digits, the proportion of the company prefix and the serial reference can be selected from the
seven combinations described in the table below.
Partition value
Company prefix digits
Serial reference digits
0
12
5
1
11
6
2
10
7
3
9
8
4
8
9
5
7
10
6
6
11
In this example, according to the table above,
Company prefix digit number: 7
Serial reference digit number: 10
The partition value is 5, but since this value is generated within the printer, it is not necessary to be specified.
When the standard format is used
<IP0>e:h,enc:a,com:4011661,srl: 3000000001,flt:0;
Description of each parameter
e:h,------------- Specifies the standard format
enc:a------------ Specifies SSCC96 code conversion
com:4011661,----- The company prefix is 4011661
srl:3000000001,-- The serial reference is 3000000001 17 digits when combined with com:
flt:0 ----------- The filter value is All Others
;---------------- End terminal
When the one-character parameter identifier in the conventional format is used
<IP0>e:a,c:7,s:10,f:0,d:40116613000000001;
Description of each parameter
e:a,-------------- Specifies SSCC96 code conversion
c:7,-------------- The company prefix is 7 digits
s:10,------------- The serial reference is 10 digits 17 digits when combined with c:
f:0,-------------- The filter value is All Others
d:40116613000000001 –Number in which the company prefix and serial reference are joined together It is 17 digits.
;---------------- End terminal
When these commands are executed, the above parameters are converted to SSCC96 code
3114F4DA34B2D05E01000000 and 24 characters (18 characters in actuality), and are written in a tag.

Table of Contents