313
Tag chip manufacturer setting (Default: 0)
0 (30H) : IMPNJ
1 (31H) : ALIEN
2 (32H) : NXP
Pre-encoded tag setting (Default: 0)
0 (30H) : Disable
1 (31H) : Enable
MCS prefix number of digits setting (Default: 0)
Set from 0 digit to 3 digits.
MCS prefix insertion setting (Default: 0)
0(30H) : AUTO
1(31H) : MANUAL
MCS prefix data setting (Default: 0)
0 (30H) : 0
1 (31H) : 01
2 (32H) : 10
3 (33H) : 11
|
7 (37H): 111
RFID log setting (Default: 0)
0 (30H) : Disable
1 (31H) : Enable
RFID log data setting (Default: 0)
0 (30H) : EPC and TID
1 (31H) : EPC
2 (32H) : TID
1. The parameter that doesn't need to be changed can be omitted.
2. When omitted the item, the previous value will be maintained. (Excluding Rs:Rc: parameter)
3. When there is an error in a part of parameter, the other parameters specified together are disabled.
4. When changed the setting of parameter that is necessary to reboot after changing, make sure to specify rebooting.
[Coding Example]
<A>
<RA>2,Ec:03,Ce:0,Rs:0
<Z>
Explanation: the printer is configured to RFID enabled, the number of retries is 3, and do not print at command error.
The printer is not rebooted after execution of this command.
[Notes]
1. This command is valid only for the RFID option equipped printer.
2. This command cannot use together with other than <A><Z> command.
3. There are 3 long beeps and the printer is rebooted automatically when this command is sent to the printer.
When rebooting is not necessary, specify the parameter "Rs:0". There are 3 short beeps when the printer is not rebooted.
Specify "Rs:2" when rebooting and buzzer sound is not necessary.
4. Be sure to feed one label for adjusting the position after rebooting.
5. When changed the setting of parameter that is necessary to reboot after changing, make sure to specify rebooting.
6. The setting values of the menus listed below are changed accordingly by changing the value with this command.
Extended parameters that values are changed accordingly and menu screens
Screens changed accordingly
RFID module setting screen
MAX. ERR COUNT setting screen
RFID_TAG OFFSET setting screen
ANTENNA POWER setting screen
ANTENNA POWER setting screen
RFID RETRY MODE setting screen
RFID ERR SLASH setting screen
RFID ERR OUTPUT setting screen
LENGTH OF PULSE setting screen
PREND TYPE 3/4 setting screen
INVENTRY setting screen ENABLE/DISABLE
INVENTRY setting screen TIMEOUT