4 Operation and Configuration
121
SG112-ex Operator Manual
EXTERNAL SIGNAL
Set the output signal type of the print end signal (PREND).
The following options are available:
Note
• Shows only if EXTERNAL SIGNAL is set to ENABLE.
• Refer to the Timing Chart of the EXT Input Signal for details.
EXTERNAL REPRINT
Set the reprint function by reprint signal (PRIN2) from the external signal
(Pin 7).
• ENABLE: Enable the reprint when no print quantity is remaining.
• DISABLE: Disable the reprint.
Note
The product will not reprint if a command error occurs.
SET CALENDAR
Select whether or not to set the calendar.
• YES: Proceed to the calendar setting screen.
• NO: Proceed to the AUTO ONLINE screen.
Note
Shows only if the real-time clock (calendar) kit is installed.
Type Operation Details
TYPE1 The print end signal (PREND) is High before label
printing, and it becomes Low after print completion. The
signal level becomes High after 20 ms.
TYPE2 The print end signal (PREND) is Low before label
printing, and it becomes High after print completion. The
signal level becomes Low after 20 ms.
TYPE3 The print end signal (PREND) is High before label
printing, becomes Low from the start to the end of print,
and becomes High again after print completion.
TYPE4 The print end signal (PREND) is Low before label
printing, becomes High from the start to the end of print,
and becomes Low again after print completion.