8 Appendix
207
SG112-ex Operator Manual
8.7.5
No Pulse Input in Tear-off Mode (Head Check Disabled)
(1) Operation
(2) Timing chart
Label feed
Cut
PRIN
Ext.signal
PREND(TYPE1)
PREND(TYPE2)
PREND(TYPE3)
PREND(TYPE4)
Head check
Operation
Backfeed
Print 2nd label
Power ON
Print 1st label
Feed
Time specified by <TW>.
500ms
0HGLDIHHGGLUHFWLRQ
ձ
ղ
ճ
Manual Cut Pitch Sensor
(
Ga
p)
ձ
ղ
ճ
Backfeed to the Print Base position
Standby
ձ
ղ
ճ
մ
ձ
ղ
ճ
մ
յ
Print 1st label
Print 2nd label
Print head
մ
ձ
ղ
ճ
մ
յ
ն
Feed to the
manual cut position
(Note)
The base position using the Gap sensor is shown above.
*1 The time specified by <TW> lapses.
*1 The media is fed to the manual cut position when time (option unit stand-by time; default value -
1000ms) specified by <TW> lapses and no print job is sent.