8 Appendix
203
SG112-ex Operator Manual
8.7.1
Continuous Mode, Pitch Sensor Enabled and No Pulse Input
(Head Check Disabled)
(1) Operation
(1) (2) (3)
Print head
Pitch sensor
(
Ga
p)
(1) (2) (3) (4)
Print the 1st label
Standby
(1) (2) (3) (4) (5)
(1) (2) (3) (4) (5) (6)
Print the 2nd label
Print the
3
rd label
(Note)
The positions shown above are the base reference point when using the Gap sensor.
(2) Timing chart
Label feed
PRIN
External signal
PREND (TYPE1)
PREND (TYPE2)
PREND (TYPE3)
PREND (TYPE4)
Head check
Operation
Print the 1st label
Print the 2nd label
Print the 3rd label
Power ON
Media feed direction

Table of Contents