EasyManua.ls Logo

SATO SG112-ex - No Pulse Input in Tear-Off Mode (Head Check Enabled)

SATO SG112-ex
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Appendix
208
SG112-ex Operator Manual
8.7.6
No Pulse Input in Tear-off Mode (Head Check Enabled)
(1) Operation
(2) Timing chart
0HGLDIHHGGLUHFWLRQ
ձ
ղ
ճ
Manual Cut Pitch Sensor
(
Ga
p)
ձ
ղ
ճ
Backfeed to the Print Base position
Stand-by
ձ
ղ
ճ
մ
ձ
ղ
ճ
մ
յ
Print 1st label
Print 2nd label
Head
մ
ձ
ղ
ճ
մ
յ
ն
Feed to the
manual cut position
(Note)
The base position using the Gap sensor is shown above.
*1 The time specified by <TW> lapses.
*1 The media is fed to the manual cut position when time (option unit stand-by time; default value -
1000ms) specified by <TW> lapses and no print job is sent.
Label feed
Cut
PRIN
Ext. signal
PREND(TYPE1)
PREND(TYPE2)
PREND(TYPE3)
PREND(TYPE4)
Head check
Operation
Backfeed
Print 2nd label
Power ON
Print 1st label
Feed
500ms Time specified by <TW>.

Table of Contents

Other manuals for SATO SG112-ex

Related product manuals