8 Appendix
193
SG112-ex Operator Manual
8.2
Download and Upload Specification
The following table shows the download and upload specification using the interface and memory card.
Note about downloading
If the file does not exist when selecting the item to be downloaded, that item cannot be selected.
The font size of “Configuration” and “Font/logo” are different depending on the head density. Do not
download anything between the products with different head density.
The download file for “Kanji font” varies depending on Chinese/Japanese font.
For “Configuration”, the items listed in the default list will be downloaded (excluding Life Counter, Head
Counter, Cut Counter, MAC Address, BD Address, Main PCB REV, PLD VERSION and PCB Number).
Note about uploading
When the same file already exists in the save location, the existing file is overwritten.
An error is raised when the folder to be uploaded cannot be found. Format the card in the Memory mode
before uploading.
Write protected SD card or USB memory will cause an error when uploading. Release the write protection
from them before uploading.
Not having enough available memory in SD card or USB memory will cause an error when uploading.
The date of file creation is according to the calendar if the real-time clock (calendar) kit is installed. If not, the
file creation date will be indicated by the firmware release date.
For “Configuration”, the current contents of the items listed in the default list will be uploaded.
Target item
SD card/
USB
memory
Interface
Remarks
Program download
Firmware O O
Kanji outline font O O
Kanji font O O
Configuration (settings) O O
Font/logo O O
Files that are uploaded in the upload mode are down-
loaded.
TTF O O
Files that are uploaded in the upload mode are down-
loaded.
Receive buffer X X
STATUS5 log X X
All O X All the items with “O” above are downloaded.
Program upload
Firmware O X
Kanji outline font O X
Kanji font O X For NEC font, upload is not available.
User mode information O X
When “All” is selected, both binary format and text for-
mat files are uploaded. (Normally text format file only)
Font/logo O X
TTF O X
Receive buffer X X It is possible to upload in the receive data save mode.
STATUS5 log O X
All O X All the items with “O” above are downloaded.