MRD 3187B - User Manual
Page 152 (245)
Each Mode allows the following to be changed:
User: Compression, Downmix, Dynamic Range
Monitor: Compression
Transmission: no changes
Compression
1. Use the and buttons to move
the cursor to “Compress:” then press
the button.
2. Use the and buttons to
select the desired compression (“RF
Mode”, “Line Mode”, “Custom 0”,
“Custom 1”) then press the
button to save the selection.
Downmix
1. Use the and buttons to move
the cursor to “Ch Downmix:” then
press the button.
2. Use the and buttons to
select the desired downmix (“2/0 LR”,
“2/0 Auto”, “2/0 LtRt”, “MonoChan1”,
“MonoChan2”) then press the
button to save the selection.
Note: The “2/0 Auto” is used by Dolby Digital Plus (EAC3) to use “2/0 LR” or “2/0
LtRt” based on the received audio metadata. If the metadata is not present,
like for Dolby Digital (AC3), “2/0 LtRt” is used.
Dynamic Range
1. Use the and buttons to move
the cursor to “Dyn Range:” then press
the button.
2. Use the and buttons to set
the Dynamic Range to “Enabled” or
“Disabled”, then press the button
to save the selection.
Source ID Setup
There are two modes that the Source ID can be obtained – Auto or Manual. In Auto
mode, the unit attempts to discover the Source ID that is signaled in the stream. The
user specifies a timeout for the length of time the unit searches for the Source ID in
the stream. If not found, the user entered name is used. In Manual mode, the user
entered name is used. To setup the Source ID, use the following steps:
Aud 1 Setup
Compress:RF Mode
Ch Downmix:2/0 LR
►Dyn Range:Enabled
Aud 1 Setup
Mode:User
Compress:RF Mode
►Ch Downmix:2/0 LR
Aud 1 Setup
Mode:User
►Compress:RF Mode
Ch Downmix:2/0 LR