4 START-UP AND PARAMETER SETTINGS
Fig. 44: SOPAS ET menu: DH T200/Adjustment/Manual Adjustment/Transmission set reference
Check whether the value 100% is displayed in window “Transmission reference value”
(see “SOPAS ET menu: DH T100/Adjustment/Manual Adjustment/Transmission set ref-
erence”, page 64, see “SOPAS ET menu: DH T50/Adjustment/Manual Adjustment/
Transmission set reference”, page 67 or Fig. “SOPAS ET menu: DH T200/Adjustment/
Manual Adjustment/Transmission set reference”) after this process is completed. When
the deviations (< approx. 1%) are small, click the “Set reference” button, when the
deviations are large, repeat setting of reference.