Display Possible cause Remedy
The addresses of both
t
he host device and the
guest device may have
been set to guest.
A device connected via
EFI or the connection to
the device is defective
or disrupted.
b
R
emove the jumper on the host device.
b
Check the connected device and the connec‐
tion to this device.
Undervoltage of the sup‐
pl
y voltage
b
Chec
k the power supply unit and the connect‐
ing cables.
There is a short-circuit
be
tween the input for
the control switch for
restart or reset and
another input or output.
b
Chec
k the wiring for cross-circuits.
Input signal for a non-
de
fined monitoring case
b
Chec
k the path of the vehicle.
Or:
b
Check the operating process of the monitored
machine or system.
b
If necessary, check the configuration of the
monitoring cases using the CDS.
Incorrect sequence
when s
witching the mon‐
itoring cases
Incorrect operation of
the control inputs via EFI
b
Chec
k the operation of the digital control
inputs.
Incorrect operation of
A1/2 v
ia EFI
b
Chec
k the operation of the digital control
inputs.
Incorrect operation of
B1/2 v
ia EFI
Incorrect operation of
C1/2 via EFI
Incorrect operation of
D1/2 via EFI
Incorrect operation of
E1/2 v
ia EFI
Park/standby mode,
the OSSDs are in the
OFF state; the laser is
switched off.
Not an error. Operational readiness is restored
when the criteria for the park mode or standby
mode are withdrawn.
If the display does not go out:
b
Test the level(s) at the STBY input and at the
control inputs that switch to the monitoring
case with park mode.
A device connected via
E
FI reports a malfunc‐
tion.
b
C
arry out a fault diagnosis of the device con‐
nected to the affected device.
Optics cover calibration
ac
tive
Not an error
Light emission window
on the optics cover cont‐
aminated
b
Cle
an the light emission window on the optics
cover.
TROUBLESHOOTING 10
8014170/ZA23/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S300 Mini
105
Subject to change without notice