2 On safety
This chapter deals with your own safety and the safety of the equip-
ment operators.
= Please read this chapter carefully before working with the TR4 or with
the machine protected by the TR4.
2.1 Qualified safety personnel
The TR4 safety switch must be installed, connected, commissioned and
serviced only by qualified safety personnel. Qualified safety personnel
are defined as persons who …
due to their specialist training and experience have adequate knowl-
edge of the power-driven equipment to be checked
and
who have been instructed by the responsible machine operator in the
operation of the machine and the current valid safety guidelines
and
are sufficiently familiar with the applicable official health and work
safety regulations, directives and generally recognized engineering
practice (e.g. DIN standards, VDE stipulations, engineering regula-
tions from other EU member states) that they can assess the work
safety aspects of the power-driven equipment
and
have access to the operating instructions and have read them.
As a rule these are qualified safety personnel from the manufacturer of
the protective device or also persons who have been appropriately
trained at the manufacturer of the protective device, are primarily in-
volved in checking protective devices and are allocated the task by the
organization operating the protective device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK TR4 and is the answer not in the manual?

SICK TR4 Specifications

General IconGeneral
Number of Safe Outputs2
Output TypePNP
Protection RatingIP67
TypeSafety Switch
Housing MaterialPlastic
Supply Voltage24V DC
Connection TypeCable
Operating Voltage24 V DC
Operating Temperature-25 °C ... +70 °C
Actuator TypeSeparate actuator (TR4 Direct, TR4 Standard, TR4 Extended)