Operating Instructions Chapter 3
TR4
8014467/YTD7/2016-03-30 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 65
Subject to change without notice
Product description
en
Magnetic retaining force
The safety switches of type TR4-SFxxxx are equipped with built-in
magnets. These magnets draw the actuator to the sensor with their
retaining force such that the guard (e.g. a protective door) is retained
with a certain force. This feature makes more difficult the unintentional
opening of the guard in case of disturbances such as shock and vibra-
tion and increases the availability of the machine.
3.2 Safety features
The TR4 safety switch has the following safety features:
SIL3 according to IEC 61 508
category 4 according to EN ISO 13 849-1
PL e according to EN ISO 13 849-1
type 4 according to EN ISO 14 119
TR4 Multicoded: low level coded actuator
TR4 Unique Coded: high level coded actuator
Operational safety
The TR4 safety switch has the following internal protective functions:
short-circuit protection on all outputs
overload protection on all outputs
reverse polarity protection of the operating voltage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK TR4 and is the answer not in the manual?

SICK TR4 Specifications

General IconGeneral
Number of Safe Outputs2
Output TypePNP
Protection RatingIP67
TypeSafety Switch
Housing MaterialPlastic
Supply Voltage24V DC
Connection TypeCable
Operating Voltage24 V DC
Operating Temperature-25 °C ... +70 °C
Actuator TypeSeparate actuator (TR4 Direct, TR4 Standard, TR4 Extended)