Advanced commissioning
6.5 Motor control
Converter with the CU240B-2 and CU240E-2 Control Units
238 Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
Default setting after selecting the application class Standard Drive Control
Selecting application class Standard Drive Control in the quick commissioning adapts the
structure and the setting options of the U/f control as follows:
● Starting current closed-loop control: At low speeds, a controlled motor current reduces
the tendency of the motor to oscillate.
● With increasing speed, transition from closed-loop starting current control into U/f control
with voltage boost depending on the load.
● Soft starting is not possible.
● Fewer parameters
Image 6-31 Default setting of the U/f control after selecting Standard Drive Control
The complete function diagrams 6850 ff. for application class Standard Drive Control are
provided in the List Manual.