Advanced commissioning
6.8 Safe Torque Off (STO) safety function
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
333
p0010 = 95
Drive commissioning parameter filter
Safety Integrated commissioning
p9601
Enable functions integrated in the drive
(factory setting: 0000 bin)
Basic functions via onboard terminals
p9761
(factory setting: 0000 hex)
Permissible passwords lie in the range 1 … FFFF FFFF.