Technical data
10.3 Technical data, Power Modules
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
463
Table 10- 39 PM230, IP20, frame sizes A, 3 AC 380 V … 480 V
Article No. - without filter
Article No. - with filter
LO base load power
LO base load input current
LO base load output current
3 kW
8.0 A
HO base load power
HO base load input current
HO base load output current
2.2 kW
6.1 A
Fuse according to IEC
3NE1 813-0
Required cooling air flow
Cross section of line and motor cables 1.5 … 2.5 mm
2
Tightening torque for line and motor cables
Weight without filter
1.4 kg
Table 10- 40 PM230, PT, frame sizes A, 3 AC 380 V … 480 V
Article No. - without filter
Article No. - with filter
LO base load power
LO base load input current
LO base load output current
3 kW
8.0 A
HO base load power
HO base load input current
HO base load output current
2.2 kW
6.1 A
Fuse according to IEC
Fuse according to UL
3NE1 813-0
AJT10 / 3NE1 813-0
Power loss 0.11 kW
Required cooling air flow
Cross section of line and motor cables 1.5 … 2.5 mm
2
Tightening torque for line and motor cables 0.5 Nm / 4 lbf in
Weight without filter
1.7 kg