EasyManua.ls Logo

Siemens CU240B-2 - Page 468

Siemens CU240B-2
518 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
10.3 Technical data, Power Modules
Converter with the CU240B-2 and CU240E-2 Control Units
468 Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
Current reduction depending on pulse frequency
Table 10- 48 Current reduction depending on the pulse frequency
1)
LO base
load
Output base-load current at a pulse frequency of
2 kHz
4 kHz
6 kHz
8 kHz
10 kHz
12 kHz
14 kHz
16 kHz
kW
A
A
A
A
A
A
A
A
0.37
--
1.30
1.11
0.91
0.78
0.65
0.59
0.52
0.55
--
1.70
1.45
1.19
1.02
0.85
0.77
0.68
0.75
--
2.20
1.87
1.54
1.32
1.10
0.99
0.88
1.1
--
3.10
2.64
2.17
1.86
1.55
1.40
1.24
1.5
--
4.10
3.49
2.87
2.46
2.05
1.85
1.64
2.2
--
5.90
5.02
4.13
3.54
2.95
2.66
2.36
3.0
--
7.70
6.55
5.39
4.62
3.85
3.47
3.08
4.0
--
10.20
8.67
7.14
6.12
5.10
4.59
4.08
5.5
--
13.20
11.22
9.24
7.92
6.60
5.94
5.28
7.5
--
18.00
15.30
12.60
10.80
9.00
8.10
7.20
11.0
--
26.00
22.10
18.20
15.60
13.00
11.70
10.40
15.0
--
32.00
27.20
22.40
19.20
16.00
14.40
12.80
18.5
--
38.00
32.30
26.60
22.80
19.00
17.10
15.20
22
--
45.00
38.25
31.50
27.00
22.50
20.25
18.00
30
--
60.00
51.00
42.00
36.00
30.00
27.00
24.00
37
--
75.00
63.75
52.50
45.00
37.50
33.75
30.00
45
--
90.00
76.50
63.00
54.00
45.00
40.50
36.00
55
--
110.0
93.50
77.00
66.00
55.00
49.50
44.00
75
--
145.0
123.3
101.5
--
--
--
--
1)
The permissible motor cable length also depends on the cable type and the selected pulse fre-
quency.

Table of Contents

Other manuals for Siemens CU240B-2

Related product manuals