Page 160 MultiRanger 100/200 – INSTRUCTION MANUAL 7ML19981FB05
mmmmm
Parameters
P330 Profile Record
Records profiles for later viewing.
In addition to being a profile records library, this provides two functions:
manually records and saves echo profiles
displays an echo profile, recorded manually or automatically
To select a record address
1. Enter PROGRAM mode and press DISPLAY twice to highlight the index field.
The field shows two underscores _ _.
2. Type the index number. The profile record information is shown.
3. Use ARROWS to scroll through the records.
To manually record a profile
Press TRANSDUCER to fire the transducer and record the echo profile into the
internal buffer for display.
MultiRanger 100 and MultiRanger 200 Features
To save a manual record
Press ENTER to copy the echo profile record in the buffer and save it in the selected
address in the record library. The parameter value field displays the new record
information.
Primary Index Echo profile
Values
Code Description
---- no record
A1 automatically recorded profile from Transducer One
A2 automatically recorded profile from Transducer Two
U1 manually recorded profile from Transducer One
U2 manually recorded profile from Transducer Two