7ML19981FB05 MultiRanger 100/200 – INSTRUCTION MANUAL Page 161
mmmmm
Parameters
To display a record
Press key to enter display auxiliary mode and then:
• Press TRANSDUCER to copy the current echo profile into the buffer for display
on Dolphin Plus
To delete a record
Press CLEAR and then ENTER to delete the echo profile record in the selected
address. The value returns to - - - -.
P331 Auto Record Enable
Use to enable/disable the Auto Profile Record function.
P332 Auto Record Transducer
Specifies the Transducer Point Number for which Auto Profile Records are saved.
Please note that Differential and Average operation is a MultiRanger 200 feature.
MultiRanger 200
This feature is preset to Point Number 1. (Alteration is only required if differential or
average Operation [P001 = 4 or 5] is selected.)
Primary Index Global
Values
Range: 0 to 1
0* Off
1On
Primary Index Global
Values
Range: 0 to 2
0 Any transducer
1* Transducer One
2Transducer Two
Altered By • P001 Operation = 4 or 5