Loading...
Function diagram
87654321
fp_mc_520_e.vsd
Status diagram
MASTERDRIVES MC
23.11.01
-520 -
V2.5
Error acknowledgement
after init. fault
P060 = 3, 6
START
Initialization
states
SWITCH-ON
INHIBIT
(8)
P060 = 7, 5
READY FOR
SWITCHING ON
(9)
ON or jogging
PRECHARGING
(10)
Precharging finished
READY FOR
OPERATION
(11)
INV stop
OPERATION
(14)
INV release
OFF_WITH_
FASTSTOP
(OFF3) (16)
OFF_WITH_
RGEN_REV
(OFF1) (15)
OFF3
OFF1
OFF3
FAULT
(7)
No ON
or jogging
OFF2/3 or
"Illegal ON" <1>
P060 = 4, 5
OFF command
B0270
OFF2,
SAFE STOP
OFF2 or
SAFE STOP or
OFF switch-off
speed reached
P060 = 3, 6
OFF2 or
INV stop or
SAFE STOP or
OFF switch-off
speed reached
All components
ready
Acknowledgement
from all
states
<1> Switch-on with e.g. P554.B = 1 is not permissible!