...functions
Synchronism...
Real master
Virtual master axis
Function diagram
87654321
fp_mc_802_e.vsd
Technology option
MASTERDRIVES MC
08.01.02
Technology overview, operating mode manager
-802 -
Operating modes
Input signals
Machine
data
[804]
Quick para-
meterization
[806]
Parameter download file
"Positioning via bus"
CD-ROM
Positioning control signals
Control bits
[809]
Operating
mode
[809]
[MODE_IN]
0 ... 11
Digital inputs
for positioning
[813]
Override
[809]
Position signals
[815]
Basic unit
control bits
[818]
Evaluation of
position sensing
<1>
Mode 3:
MDI
(Point-to-point
positioning)
Mode 2:
Homing procedure
(approaching the reference
point, only with incremental
position encoders, e.g. Re-
solvers, ERN encoders,
pulse encoders)
Mode 1:
Set-up
(position controlled inching
taking into account the soft-
ware limit switch)
Mode 4:
Control
(speed-controlling inching
without taking into account
the software limit switch)
[825]
[823]
[821]
[819]
Modes 5 and 6:
Automatic
(Automatic run-through of
traversing programs)
[826...828]
.
.
.
MD45, MD46
Mode 11:
Synchronism
Overview
[831]
[832]
[833]
[834]...
...[843]
<3>
<3>
<2>
<2>
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Check
Operating
mode
manager
Operation mode
Positioning
status signal
[811]
Digital outputs
for positioning
[813]
Control signals
for position
sensing
[815]
Setpoint output
and release
[817]
Faults
Diagnosis
[818]
A129...A255
~
External
encoder
Position
sensing for
motor encoder
[330] or
external
encoder [335]
Speed
sensing
[500]
s
act.
+
M
~
~
Motor
encoder
+
+
+
n
ist
Speed
controller [360]
Position
controller [340]
[340]
[370]
a*
n*
s*
Basic unit
Sampling times
<1> Sampling time for the positioning
modes:
Recommended: U953.32 = 4
<2> Sampling time for synchronism:
U953.33 = 20 => Synchronism as a
positioning mode inserted in the
sampling time determined by U953.32
U953.33 < 20 => Synchronism operates
as autonomous free block with its own
input/output signals; only permitted if
positioning modes are deactived
(i.e. if U953.32 = 20)
<3> Sampling time for virtual...
... and real master axis:
The virtual and real master axes are
independent free blocks.
[802.2]
[MODE_IN]
V2.5
U501
U502
U710
U530
U536
[MODE_OUT]
n540.14 [811]
n540
KK0315
U953.32 = ___(20)
U953.33 = ___(20)
U953.34 = ___(20)
U953.31 = ___(20)
n540.14
B0351...362
B0311...316
Simulation mode
U503