Parameter
Description Data Read/write
n690
PosOutput VMAx
2690
Visualization parameter:
Position setpoint at output of virtual master axis [LU].
Function diagram [832.8]
Dec.Plc.: 0
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
- Upread/free access
n691
Speed OutpVMAx
2691
Indication of speed setpoint of the virtual master axis in
[10*LU/min]
Function diagram [832.8]
Dec.Plc.: 0
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
- Upread/free access
n692
Speed Setp VMAx
2692
The visualization parameter displays the speed setpoint at
the input of the virtual master axis in [10*LU/min]
Function diagram [832.3]
Dec.Plc.: 0
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
- Upread/free access
U693
SetV VMAx
2693
Fixed setpoint for the set value of the virtual master
(master axis).
With [S_VM] U684.03 set master axis to initial position,
the distance in the axis cycle is set via this fixed
connector.
Init: 0
Min: -
2147483647
Max:
2147483647
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U694*
Adjust_DispAngle
2694
Index 1: 0->1 Increase displacement angle
Index 2: 0->1 Decrease displacement angle
index1: 0
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U695*
Adj.Spd Para
2695
The adjusting speed for manual adjustment is specified
here via binectors U696.1 (+) and U696.2 (-).
index1:
60000,00
Min: 0,00
Max:
20000000,00
Unit: -
Indices: 3
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U696*
DispAngle+
2696
Index 1:
Displacement angle +
0 : no adjustment
1 : continuous displacement alteration
Index 2:
Displacement angle -
0 : no adjustment
1 : continuous displacement alteration
index1: 0
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U697*
Offset Corr Par
2697
Index 1:
Acceleration of the displacement angle correction
[1000*LU/s^2]
Index 2:
Speed of the displacement angle correction
[1000*LU/min]
In function diagram 841
index1: 0,00
Min: 0,00
Max:
20000000,00
Unit: -
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U698*
OffstCorrVFactor
2698
INDEX 1:
Speed adjustment in percent for U697.2
INDEX 2:
Speed adjustment in percent for U695.1
index1: 1
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled