Parameter
Description Data Read/write
U699*
Mode Correct
2699
Index 1: Master value synchronization
0 = shortest distance
1 = only positive direction
2 = only negative direction
3 = only positive direction with window
4 = only negative direction with window
Index 2: Displacement angle absolute
0 = shortest distance
1 = prescribed direction
2 = prescribed direction
index1: 0
Min: 0
Max: 4
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U700*
SrcRegisterKK
2700
[FP842] Register decoupling
Index 1: Register displacement
Adaptation of circumference
Index 2: Register displacement
Decoupling from predecessor
Index 3: Register displacement
Setting value
Index 4: Register displacement
Offset angle
Index 5: Register displacement
Offset angle speed
Index 6: Register decoupling
Decoupling
Index 7: Register decoupling
Adjustment speed of printing cylinder
Index 8: Register decoupling
Current angular speed of printing cylinder
Index 9: Register decoupling
Current circumference
index1: 799
Unit: -
Indices: 9
Type: L2 ,K
,K
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U701*
SrcRegisterB
2701
[FP842] Register decoupling
Index 1: Register displacement
Enable register displacement
Index 2: Register displacement
Setting command
Index 3: Register decoupling
Enable register decoupling
index1: 820
Unit: -
Indices: 3
Type: L2 ,B
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U702*
Adaptation
2702
[FP842] Register decoupling
Index 1: Register displacement
Adaptation of speed
Index 2: Register decoupling
Adaptation of speed
Index 3: Register decoupling
Adaptation of time constant T1
index1:
100,00
Min: 0,00
Max: 200,00
Unit: %
Indices: 3
Type: I2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U703*
GenParam
2703
[FP842] Register decoupling
Index 1: Register displacement
Axis cycle
Index 2: Register decoupling
Circumference
Index 3: Register decoupling
Normalization of circumference
Index 4: Register decoupling
Distance printing position
index1: 4096
Min: 1
Max:
2147483647
Unit: -
Indices: 4
Type: O4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U704*
Normalization
2704
[FP842] Register decoupling
Index 1: Register displacement
Normalization of speed
Index 2: Register decoupling
Normalization of web speed
index1: 0,00
Min: 0,00
Max:
20000000,00
Unit: -
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
219