Parameter
Description Data Read/write
U893*
Tab Y551-Y600
2893
With this parameter, Y interpolation points 551 to 600 are
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
index1: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: 50
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U894*
Tab Y601-Y650
2894
With this parameter, Y interpolation points 601 to 650 are
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
index1: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: 50
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U895*
Tab Y651-Y700
2895
With this parameter, Y interpolation points 651 to 700 are
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
index1: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: 50
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U896*
Tab Y701-Y750
2896
With this parameter, Y interpolation points 701 to 750 are
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
index1: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: 50
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U897*
Tab Y751-Y800
2897
With this parameter, Y interpolation points 751 to 800 are
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
index1: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: 50
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
n900
ObjectData
2900
Service parameter, only for Siemens personnel
Visualization parameter for interconnecting connectors
and binectors according to the setting in U905.
The connector and binector parameters and the
respective index are listed with which the connector or
binector is linked in U905.2.
Index 1 Function number of the first interconnection
Index 2 Parameter number
Index 3 Index
Index 4 Function number of the second interconnection
Index 5 Parameter number
Index 6 Index
Dec.Plc.: 0
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
- Upread/free access
n901
ObjectData
2901
Service parameter, only for Siemens service personnel Dec.Plc.: 0
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
- Upread/free access
248
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control