EasyManua.ls Logo

Siemens simovert masterdrives

Siemens simovert masterdrives
1547 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connector number Connector name Description Double wordDSP
K3001 ... K3016 CB/TB Word Received process data from CB/TB
In function diagram: 120.5
no
no
KK3031 ... KK3045 CB/TB DWord Received process data from CB/TB
In function diagram: 120.6
yes
no
K4101 ... K4103
not Compact PLUS
SCI Sl.1 AnaIn SCI1 Analog inputs Slave 1
In function diagram: Z20.7
no
no
K4201 ... K4203
not Compact PLUS
SCI Sl.2 AnaIn SCI slave 2 Analog inputs
In function diagram: Z21.8
no
no
K4501 ... K4516
not Compact PLUS
SCB Word SCB 16-bit setpoints
In function diagram: Z01.6, Z05.6
no
no
KK4531 ... KK4545
not Compact PLUS
SCB DWord SCB 32-bit setpoints
In function diagram: Z05.7
yes
no
K5101 1st EB1 AnaIn1 Analog input 1 of the first inserted EB1
In function diagram: Y01.8
no
no
K5102 1st EB1 AnaIn2 Analog input 2 of the first inserted EB1
In function diagram: Y01.8
no
no
K5103 1st EB1 AnaIn3 Analog input 3 of the first inserted EB1
In function diagram: Y01.8
no
no
K5104 1st EB1 AnaOut1 Setpoint, analog ouptut 1 of the first
inserted EB1
In function diagram: Y02.5
no
no
K5105 1st EB1 AnaOut2 Setpoint, analog output 2 of the first
inserted EB1
In function diagram: Y02.5
no
no
K5106 1EB1stat.DI/DO Display of status of the terminals
(status of digital inputs/outputs) of the
first inserted EB1
In function diagram: Y03.2
no
no
K5111 AnaIn 1st EB2 Analog input of the first inserted EB2
In function diagram: Y07.8
no
no
K5112 AnaIn 1st EB2 Setpoint, analog output of the first
inserted EB2
In function diagram: Y07.5
no
no
K5113 Stat.DI/DO 1EB2 Display of status of the terminals
(status of digital inputs/outputs) of the
first inserted EB2
In function diagram: Y07.3
no
no
K5201 2nd EB1 AnaIn1 Analog input 1 of the second inserted
EB1
In function diagram: Y04.8
no
no
K5202 2nd EB1 AnaIn2 Analog input 2 of the second inserted
EB1
In function diagram: Y04.8
no
no
K5203 2nd EB1 AnaIn3 Analog input 3 of the second inserted
EB1
In function diagram: Y04.8
no
no
K5204 2nd EB1 AnaOut1 Setpoint, analog output 1 of the
second inserted EB2
In function diagram: Y05.5
no
no
K5205 2nd EB1 AnaOut2 Setpoint, analog output 2 of the
second inserted EB1
In function diagram: Y05.5
no
no
K5206 2EB1stat.DI/DO Display of status of the terminals
(status of digital inputs/outputs) of the
second inserted EB1
In function diagram: Y06.2
no
no
K5211 AnaIn 2nd EB2 Analog input of the second inserted
EB2
In function diagram: Y08.8
no
no
28
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control

Table of Contents

Other manuals for Siemens simovert masterdrives