Function diagram
87654321
fp_mc_160a_e.vsd
SIMOLINK board
MASTERDRIVES MC
23.10.02
Transmitting special data
- 160a -
V2.5
Special data
1
2
3
4
6
5
7
8
.01
.02
.03
.04
.05
.06
.07
.08
Double
word 1
Double
word 2
Double
word 3
Double
word 4
Notes:
Special data may only be transmitted by the dispatcher (bus address P740 = 0)!
If at least one special datum is assigned (P756.x
0), the number of addressed nodes is reduced vis-a-
vis the formula on function diagram 140:
telegram a for Time=sµ 6.36 ;
P745
1
)6
µs 6.36
sµ 3.18+P746
(= data special withnodes addressed of Number
(3.18 due to rounding off)
K
P756 (0)
SrcSLBTrnsData
K
K
K
K
K
K
K
n959.21 = 2