p0201[0] Power unit code number
Data type: Unsigned16 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Power unit
Unit: -
Min:
0
Max:
65535
Factory setting:
0
Description: Sets the actual code number of the power unit being used.
p0210 Device supply voltage
Data type: Unsigned16 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Power unit, Quick commissioning
Unit: V
Min:
1 [V]
Max:
63000 [V]
Factory setting:
400 [V]
Description: Sets the device supply voltage.
The voltage betw
een two phases should be entered as the device supply voltage.
This setting is important for operating with voltages that are less than the voltage range for which the drive is designed.
Note
Setting ranges for p0210 as a function of t
he rated power unit voltage:
U_rated = 230 V:
- p0210 = 200 ... 240 V
U_rated = 400 V:
- p0210 = 380 ... 480 V (wide voltage range, in addition to 200 ... 240 V)
p0215 Braking resistor selection
Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Dynamic braking, Quick commissioning
Unit: -
Min:
3
Max:
10
Factory setting:
10
Description: Sets the external braking resistor.
Value: 3: Third-party braking resistor (with monitoring)
10: No monitoring (external braking resistor)
Dependency: See also: p0216, p0218, p0219
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
600 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA