Description: Sets the lter time for a square-w
ave encoder.
NOTICE
If the lter time is too long, the PTI signals A/B may be suppr
essed.
r0479[0...2] Diagnostics encoder position actual value Gn_XIST1
Data type: Integer32 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Motor encoder
Unit: -
Description: Display for the encoder position actual value Gn_XIST1 according to PROFIdrive for diagnostics.
The value is displayed with sign.
Inde
x: [0] = Motor encoder
[1] = Encoder 2
[2] = Reserved
p0488[0...2] Measuring pr
obe 1 input terminal
S200 PTI Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Measuring probe, Traversing blocks
Unit: -
Min:
0
Max:
210
Factory setting:
0
Description: Sets the input terminal to connect probe 1.
Value: 0: No measuring probe
210: DI 0 (X132.5)
Index: [0] = Motor encoder
[1] = Reser
ved
[2] = Reserved
Dependency
: See also: p0489, p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
Note
DI: Digital Input
If paramet
erization is rejected, check whether the terminal is already being used in p2517 or p2518.
p0489[0...2] Measuring probe 2 input terminal
S200 PTI Data type: Integer16 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Measuring probe, Traversing blocks
Unit: -
Min:
0
Max:
211
Factory setting:
0
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2