CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
p0550[0] Brake version
Data type: Integer16 Visible in: Extended displa
y
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor holding brake, Quick commissioning
Unit: -
Min:
0
Max:
2
Factory setting:
0
Description: Sets the brake version.
Value: 0: No data
1: Holding brake
2: High performance holding brake
NOTICE
After entering a corresponding code number (p0551), this parameter is automatically pre-assigned and write
pr
otected. The inf
ormation in p0551 should be observed when removing write protection.
Note
For p0550 = 1:
The default value for opening time/closing time applies.
For p0550 = 2:
A shor
ter opening time/closing time is realized if the power unit supports the function.
p0551[0] Brake code number
Data type: U
nsigned32 V
isible in: Ext
ended displa
y
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor holding brake, Quick commissioning
Unit: -
Min:
0
Max:
4294967295
Factory setting:
1
Description: Setting the code number for the brake.
0 = No data
1 = Manual entry
> 1 = valid code number
For value = 0:
- Parameters listed under Dependent are set to a value of zero and are write protected.
- Parameters p1216, p1217 are set to a value of zero.
For value = 1:
- Write protection for the parameters listed under Dependent is withdrawn.
For value > 1:
- Parameters listed under Dependent are automatically pre-assigned and are write protected.
- Parameters p1216, p1217 are automatically appropriately pre-assigned.
Dependency: See also: p0550
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
614 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA