EasyManua.ls Logo

Siemens SINAMICS S200 - Page 616

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
p0550[0] Brake version
Data type: Integer16 Visible in: Extended displa
y
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor holding brake, Quick commissioning
Unit: -
Min:
0
Max:
2
Factory setting:
0
Description: Sets the brake version.
Value: 0: No data
1: Holding brake
2: High performance holding brake
NOTICE
After entering a corresponding code number (p0551), this parameter is automatically pre-assigned and write
pr
otected. The inf
ormation in p0551 should be observed when removing write protection.
Note
For p0550 = 1:
The default value for opening time/closing time applies.
For p0550 = 2:
A shor
ter opening time/closing time is realized if the power unit supports the function.
p0551[0] Brake code number
Data type: U
nsigned32 V
isible in: Ext
ended displa
y
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor holding brake, Quick commissioning
Unit: -
Min:
0
Max:
4294967295
Factory setting:
1
Description: Setting the code number for the brake.
0 = No data
1 = Manual entry
> 1 = valid code number
For value = 0:
- Parameters listed under Dependent are set to a value of zero and are write protected.
- Parameters p1216, p1217 are set to a value of zero.
For value = 1:
- Write protection for the parameters listed under Dependent is withdrawn.
For value > 1:
- Parameters listed under Dependent are automatically pre-assigned and are write protected.
- Parameters p1216, p1217 are automatically appropriately pre-assigned.
Dependency: See also: p0550