Note
Only code numbers can be set that ar
e permitted for the selected motor code (p0301).
p0613[0] Mot_temp_mod 1/3 ambient temperature
Data type: FloatingPoint32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Motor temperature
Unit: °C
Min:
-40 [°C]
Max:
100 [°C]
Factory setting:
20 [°C]
Description: If the thermal motor model is activated for permanent-magnet synchronous motors, then the parameter is
incorporated in the model calculation if a tem
perature sensor is not being used.
Dependency: See also: F07011, A07012
Note
If the thermal
motor model is activated for permanent-magnet synchronous motors, then the parameter is incorporated
in the model calculation if a temperature sensor is not being used.
r0721.2...7 CU digital inputs terminal actual value
S200 Basic PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Digital inputs
Unit: -
Description: Displays the actual value at the digital inputs.
This means that the actual input signal can be chec
ked at terminal DI x prior to switching from the simulation mode
(p0795.x = 1) to the terminal mode (p0795.x = 0).
Bit array: Bit Signal name 1 signal 0 signal
02 DI 2 (X132.7) High Low
03 DI 3 (X132.8) High Low
04 DI 4 (X132.9) High Low
05 DI 5 (X132.10) High Low
06 DI 6 (X132.11) High Low
07 DI 7 (X132.12) High Low
Note
DI: Digit
al Input
r0721.0...9 CU digital inputs terminal actual value
S200 PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Digital inputs
Unit: -
Description: Displays the actual value at the digital inputs.
This means that the actual input signal can be chec
ked at terminal DI x prior to switching from the simulation mode
(p0795.x = 1) to the terminal mode (p0795.x = 0).
Bit array: Bit Signal name 1 signal 0 signal
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 615