EasyManua.ls Logo

Siemens SINAMICS S200 - Page 699

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index: [0] = SI checksum to track functional changes
[1] = SI checksum to tr
ack hardware-speci󹪝c changes
Dependency: See also: p9729
r9781[0...1] SI change control time stamp days
S200 PTI Data type: Unsigned16 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Safety Integrated
Unit: -
Description: Displays the day component of the time stamp for the checksums for tracking changes for Safety Integrated.
The time stamps are g
enerated for the checksums (r9780[0...1]) (󹪝ngerprint for the "safety logbook" functionality)
Index: [0] = SI time stamp for checksum to track functional changes
[1] = SI time stamp for c
hecksum to track hardware-speci󹪝c changes
Dependency: See also: p9729, p9799
Note
The time comprises r9781 (days) and r9782 (milliseconds).
r9782[0...1] SI change control time stamp milliseconds
S200 PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Safety Integrated
Unit: ms
Description: Displays the millisecond component of the time stamp for the checksums for tracking changes for Safety Integrated.
The time stamps are g
enerated for the checksums (r9780[0...1]) (󹪝ngerprint for the "safety logbook" functionality)
Index: [0] = SI time stamp for checksum to track functional changes
[1] = SI time stamp for c
hecksum to track hardware-speci󹪝c changes
Dependency: See also: p9729, p9799
Note
The time comprises r9781 (days) and r9782 (milliseconds).
r9794 SI actual checksum safety enable
S200 PTI Data type: Unsigned32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Basic functions
Unit: -
Description: Displays the checksum over the parameters to enable the safety functions (actual checksum).
Dependency: See also: p9795
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 697

Table of Contents

Other manuals for Siemens SINAMICS S200

Related product manuals