EasyManua.ls Logo

Siemens SINUMERIK 808D ADVANCED Series

Siemens SINUMERIK 808D ADVANCED Series
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning Manual
376 6FC5397-4EP10-0BA8, 07/2018
Frame size
FSB
FSC
FSD
Overload capability
Note:
The overload capability is 150% by default. It can be set up to
200% via p0640, but the corresponding overload duration might
be reduced under the circumstances.
Control system
Servo control
Braking resistor
External
Protective functions Earthing fault protection, output short-cut protection, overvolt-
age/undervoltage protection
2)
, I
2
t detection, IGBT overtempera-
ture protection
Cooling method Fan-cooled
Environmental
conditions
Surrounding air
temperature
Operation 0 °C to 45 °C: without power derating
45 °C to 55 °C: with power derating
Storage
-40 °C to +70 °C
Ambient humidi-
ty
Operation
< 90% (non-condensing)
Storage
90% (non-condensing)
Operating environment Indoor (without direct sunlight), free from corrosive gas, combus-
tible gas, oil gas, or dust
Altitude < 1000 m (without derating)
Degree of protection
IP20
Degree of pollution
Class 2