Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
427
direction of
rotation
1004
ers override
key disable
stop
Activate handwheel (bit/binary coded)
1005
2)
Continuous
Var. INC 10000 INC 1000 INC 100 INC 10 INC 1 INC
1007
Invert
handwheel
1008
Rapid trav-
erse over-
Traversing
key disable
Feedrate
stop
Activate handwheel (bit/binary coded)
1009
2)
Continuous
Var. INC 10000 INC 1000 INC 100 INC 10 INC 1 INC
1011 Invert
handwheel
The handwheel number is represented according to the $MD_HANDWH_VDI_REPRESENTATION machine data in a
bit-coded (=0) or binary-coded (=1) manner.
Machine function: the machine function is only entered if the "INC inputs in the operating-mode signal range active"
signal (DB2600.DBX1.0) is not set.
Signals from NC channel
Status signals from NC channel
Signals from NCK channel [r]
0 Last action
block active
M0/M1
active
Approach
block active
Action
block active
Forwards
traverse
Backwards
traverse
Execution
from exter-
1 program
test active
M2/M30
active
Block
search
Handwheel
override
Rev. feder-
ate active
Referenc-
ing active
3
4 NCK alarm
with pro-
cessing
stop pre-
Channel
specific
NCK alarm
is active
Channel
operational
Stop re-
quest
Start re-
quest
Stationary Referenced