Maximum torque
3.8 7.2 10.7 14.3 21.5 25.1 28.7 35.7 50.0 70.0 90.0
-4
2)
3)
(with brake) (10
-4
2
2)
13.5
3)
Recommended load
to motor inertia ration
Weight (kg) (motor with straight connectors)
incremen-
tal en-
coder
absolute
encoder
Weight (kg) (motor with angular connectors)
incremen-
tal en-
coder
absolute
encoder
1)
When the surrounding air temperature is higher than 30 °C, the 1FL6096 motors with brake will have a power derating
of 10%;
For the motor variants with straight connectors;
3)
For the motor variants with angular connectors.
Note
The data of stall torque, rated power
, and maximum torque in the above table allows a tolerance of 10%.
For deviating conditions (surrounding air temperature > 40 °C or installation altitude > 1000 m above sea level), the
permissible torque/power must be determined from the following table. Surrounding air temperatures and installation
altitudes are rounded off to 5 °C and 500 m respectively.
Power derating as a function of the installation altitude and surrounding air temperature
Installation altitude above sea
level (m)