Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
403
Displays the smoothed field-generating actual current.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0030 Current actual
value torque-
generating
- - - Arms Float - -
Displays the smoothed torque-generating actual current.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0031 Actual torque
- - - Nm Float - -
Displays the smoothed torque actual value.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0032 Active power
actual value
- - - kW Float - -
Displays the smoothed actual value of the active power.
Significance for the drive: Power output at the motor shaft
r0033 Torque utilization
smoothed
- - - % Float - -
Displays the smoothed torque utilization as a percentage.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0037[0...19
Servo drive
- - - °C Float - -