Description of the software
6.4 Description of the menu commands
Modular Safety System 3RK3
122 System Manual, 10/2008, 926 2530-02 DS 02
6.4.5.4 Settings of Modular Safety System ES - "Logic" tab
Using the "Options" > "Settings of Modular Safety System ES" menu command, you can set
the desired behavior of the MSS ES.
"Logic" tab
It contains the following settings:
Label page transitions of connections also on screen:
Determine whether the labels of the connections on the page transitions should be visible
on the screen (default: yes).
Display terminal identifiers:
Here you can set whether the terminal identifiers are to be displayed.
"Display settings" button:
Select a display element:
The current color of the selected element is specified
You can change the color of the selected element
You can restore the basic settings
"Realign graphic" button:
If you check the control box "Avoid connections crossing functions", you can select:
Interrupt connections if possible
Move functions down
"Screen grid" button:
You can set the grid size (mm).
You can define the grid display.
You can show/hide the grid.
The graphical grid influences the moving of graphical elements.
6.4.5.5 Cross references
The "Options" > "Cross references" menu command shows the cross references in tabular
form in the output window.
6.4.5.6 Symbol list
The menu command "Options" > "Symbol list" shows the existing "plan documentation" in
tabular form in the output window.