Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02
27
Getting Started
4
4.1 Introduction
This section provides a step-by-step guide to commissioning a Modular Safety System 3RK3
(MSS) using an example demonstrating how to protect a metalworking press.
The essential steps for commissioning the MSS are as follows:
1. Installation
2. Wiring
3. Configuring
4. Function test
4.2 Hardware and software requirements
To commission the MSS in this example, you will need the following hardware and software
components:
Number Device Order number
1 3RK3 Basic 3RK3111-1AA10
1 Expansion module 2/4 F-DI 2 F-DO 3RK3231-1AA10
1 24V PELV power supply unit 6ES73071EA00-0AA0
1 Light curtain (ESPE) 3RG7846-3SB04-0SS0 (transmitter)
3RG7846-3SB04-0SS1 (receiver)
1 Pushbutton (NO contact) 3SB3801-0DD3
1 EMERGENCY STOP control device 3SB3801-0EG3
1 Two-hand operator panel 3SB3863-4BB
2 Contactors 3RT1015-1BB42
1 0.025 m connection cable 3UF7930-0AA0-0
1 PC cable 3UF7940-0AA00-0, product version 2
1 MSS ES 2008 (software) 3ZS1314-5CC10-0YA5
To configure the modules, you need a programming device or PC with the operating system
MS Windows 2000 Professional SP3 / SP4, MS Windows XP Professional SP2, or
MS Windows VISTA Business / Ultimate 32 bit.