Description of the software
6.5 Identification and configuration
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02
133
The parameters of the DP interface module are described in the following table:
Parameter name Parameter value
Configuration
Module The designation of the selected module is displayed here. The field has
a gray background and cannot be changed by the user.
Order No. The order number of the selected module is shown here. The field has
a gray background and cannot be changed by the user.
Firmware The firmware of the selected module is shown here. The field has a
gray background and cannot be changed by the user.
Equipment identifier Here you can specify a user-defined equipment identifier (max. 32
characters) for the selected module and assign it to inputs and outputs.
Inputs The number of inputs of the selected module is shown here.
Outputs The number of outputs of the selected module is shown here.
Parameter assignment
Baud rate The baud rate is automatically detected. The field has a gray
background and cannot be changed by the user.
Station address This is where you define the station address.
Station address - Change
authorizations
Here you can define the following change authorizations at the station
address:
• Changes possible without restrictions (e.g. by means of the fieldbus
command "SET_SLAVE_ADD", DS 160, or setting element).
• Can only be changed by means of data set (DS 160), which can be
sent from the controller or from the MSS ES, or by means of the
setting element (on the safety relay).
• Can only be changed by means of data set (DS 160).
Group diagnostics Here you select whether the group diagnostics is blocked or released.
If this parameter is set to "block", the parameters "Group error
diagnostics" and "Group warning diagnostics" are not significant, i.e.
they are ignored by MSS.
Group error diagnostics Here you select whether the group error diagnostics is blocked or
released.
PROFIBUS DP
Group warning diagnostics Here you select whether the group warning diagnostics is blocked or
released.
6.5.2.5 Properties of expansion modules
Description
You can open the dialog window "Properties of expansion modules" as follows:
● Double-click on a module in the configuration table.
● Select the menu option "Object properties" of the context menu (right mouse button).
● In the menu "Options" > "Settings of Modular Safety System ES" under the tab "General
settings", activate the checkbox "Display object properties automatically on insert". The
properties dialog window will then pop up automatically when you drag a module from the
catalog window into the configuration table of the project window.