EasyManua.ls Logo

Siemens SIRIUS 3RK3 - Redraw Partial Connection

Siemens SIRIUS 3RK3
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the software
6.6 Logic diagram
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02
151
Selecting a reference point
Single mouse click (on the tip of the arrow):
The reference point and the corresponding reference point are selected:
Double mouse click (on the tip of the arrow):
The corresponding reference point is selected (if necessary, the window is scrolled
down so that the corresponding reference point becomes visible):
Deleting a reference point
Select the reference point.
Delete the reference point and thus the entire connection between the respective
functions by means of the menu command "Edit" > "Delete".
You can also "Delete" via the context menu (right mouse button), command "Delete"
or by selecting the reference point + pressing the <Del> key.
Note
Special features of reference points
When a reference point or an individual partial connection is deleted, the entire
connection (including the second partial connection) is deleted.
Rerouting a partial connection at the reference point (detaching) is not possible.
Moving the reference point onto another reference point is not possible.
Moving the reference point onto a terminal is not possible.
Rerouting a partial connection at the function is possible.
6.6.4.12 Redraw partial connection
Restoring an interrupted connection
Use the menu command "Edit" > "Redraw partial connection" to restore an interrupted
connection.
Call:
Button Command
"Edit" > "Redraw partial connection"

Table of Contents