Description of the software
6.7 Functions
Modular Safety System 3RK3
206 System Manual, 10/2008, 926 2530-02 DS 02
Parameter name Description/parameter value
Q1 Select the output for the processed signal.
Q1 can only be interconnected with the output of a safe module.
Q2 Only available with output type "Redundant F output":
Select the output for the processed signal.
Q2 can only be interconnected with the output of a safe module.
Auxiliary outputs Select whether auxiliary outputs are to be activated:
No
One auxiliary output
Two auxiliary outputs
AUX1 Select the output to be processed by the function.
AUX2 Only available when two auxiliary outputs are activated:
Select the output for the processed signal.
Parameters - Output
circuit
FAULT Select the output for the processed signal.
See also
Messages for output functions (Page 268)