Getting Started
4.5 Wiring the MSS
Modular Safety System 3RK3
32 System Manual, 10/2008, 926 2530-02 DS 02
Step Action Result
5 Connect the light curtain to the central unit
of the MSS (terminal IN1/IN2) with
• Output 1 of the light curtain: Terminal
IN1
• Output 2 of the light curtain: Terminal
IN2
Note:
Please refer here to the operating
instructions for the light curtain.
/LJKWFXUWDLQV
7UDQVPLWWHU
5HFHLYHU
7
/ 0
,1 ,1 ,1 ,1
7 ,1 ,1 ,1 ,1
6 Connect the two-hand operator panel to
the central unit of the MSS with:
• NC pushbutton 1: Terminal T2/IN6
NO pushbutton 1: Terminal T1/IN5
• NC pushbutton 2: Terminal T2/IN8
NO pushbutton 2: Terminal T1/IN7
%XWWRQb
%XWWRQb
7ZRKDQGRSHUDWRUSDQHO
7
7
,1 ,1 ,1 ,1
,1 ,1 ,1 ,1
066%DVLF
'(9,&(
7 Connect the Start pushbutton on the
expansion module 2/4 F-DI 2F-DO of the
MSS with:
• NO contact: Terminal T1/IN1
6WDUW
7
7
)',)'2
,1 ,1
,1 ,1