Appendix
A.1 Process data and data sets
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
599
Byte.Bit Subindex Description Value
33.0 … 33.7 22 PWM duty cycle output 0 Duty cycle:
Factory setting: 50 %
Minimum: 10 %
Maximum: 90 %
Increment: 1 %
34.0 … 34.7 23 PWM duty cycle output 1
35.0 … 35.7 24 PWM duty cycle output 2
36.0 … 36.7 25 PWM duty cycle output 3
37.0 … 37.7 26 PWM duty cycle output 4
38.0 … 38.7 27 PWM duty cycle output 5
39.0 … 39.7 28 PWM duty cycle output 6
40.0 … 40.7 29 PWM duty cycle output 7
41.0 … 41.7 30 Dimming time, output 0 Dimming time:
Factory setting: 1 second
Minimum: 0.1 seconds
Maximum: 25.5 seconds
Increment: 0.1 seconds
42.0 … 42.7 31 Dimming time output 1
43.0 … 43.7 32 Dimming time output 2
44.0 … 44.7 33 Dimming time output 3
45.0 … 45.7 34 Dimming time output 4
46.0 … 46.7 35 Dimming time output 5
47.0 … 47.7 36 Dimming time output 6
48.0 … 48.7 37 Dimming time output 7
49.0 … 49.7 38 Input delay 0 Input delay:
Factory setting: 3 milliseconds
Minimum: 3 milliseconds
Maximum: 255 milliseconds
Increment: 1 millisecond
50.0 … 50.7 39 Input delay 1
51.0 … 51.7 40 Input delay 2
52.0 … 52.7 41 Input delay 3
53.0 … 53.7 42 Input delay 4
54.0 … 54.7 43 Input delay 5
55.0 … 55.7 44 Input delay 6
56.0 … 56.7 45 Input delay 7
57.0 … 60.7 46 Threshold I/O 0 Threshold:
Factory setting: 0 seconds
Minimum: 0 seconds
Maximum: 4294967295 seconds
Increment: 1 second
61.0 … 64.7 47 Threshold I/O 1
65.0 … 68.7 48 Threshold I/O 2
69.0 … 72.7 49 Threshold I/O 3
73.0 … 76.7 50 Threshold I/O 4
77.0 … 80.7 51 Threshold I/O 5
81.0 … 84.7 52 Threshold I/O 6
85.0 … 88.7 53 Threshold I/O 7
89.0 … 92.7 54 Threshold switching cycle counter I/O 0 Threshold switching cycle counter:
Factory setting: 0
Minimum: 0
Maximum: 4294967295
93.0 … 96.7 55 Threshold switching cycle counter I/O 1
97.0 … 100.7 56 Threshold switching cycle counter I/O 2
101.0 … 104.7 57 Threshold switching cycle counter I/O 3
105.0 … 108.7 58 Threshold switching cycle counter I/O 4
109.0 … 112.7 59 Threshold switching cycle counter I/O 5
113.0 … 116.7 60 Threshold switching cycle counter I/O 6
117.0 … 120.7 61 Threshold switching cycle counter I/O 7