Appendix
A.1 Process data and data sets
SIRIUS ACT 3SU1 pushbuttons and signaling devices
600 System Manual, 08/2018, A5E03457306020A/RS-AK/010
Byte.Bit
Subindex
Description
Value
121.0 … 121.1
62
Active edges I/O 0
Active edges: Factory setting: [0x01]
[0x00] None
[0x01] Rising edge
[0x02] Falling edge
[0x03] All edges
121.2 … 121.3 63 Active edges I/O 1
121.4 … 121.5
64
Active edges I/O 2
121.6 … 121.7 65 Active edges I/O 3
122.0 … 122.1
66
Active edges I/O 4
122.2 … 122.3
67
Active edges I/O 5
122.4 … 122.5
68
Active edges I/O 6
122.6 … 122.7
69
Active edges I/O 7
123.0
70
Inverting input 0
Inverting input:
Factory setting: [0x00]
[0x00] disable
[0x01] enabled
123.1
71
Inverting input 1
123.2
72
Inverting input 2
123.3
73
Inverting input 3
123.4
74
Inverting input 4
123.5
75
Inverting input 5
123.6
76
Inverting input 6
123.7
77
Inverting input 7
124.0
78
Inverting output 0
Inverting output:
Factory setting: [0x00]
[0x00] disable
[0x01] enabled
124.1
79
Inverting output 1
124.2
80
Inverting output 2
124.3
81
Inverting output 3
124.4 82 Inverting output 4
124.5
83
Inverting output 5
124.6
84
Inverting output 6
124.7
85
Inverting output 7

Table of Contents