Power supply: Han Q4/2 socket (connection for X1)
Socket
Assignment
1 Phase L1
2 Phase L2
3 Phase L3
4 N
11 Connector monitoring
12 Connector monitoring
PE (yellow/green)
Note
When you use the "connector monitoring" function, you have to connect pin 11 to pin 12 in
the connector.
Motor connection Han Q8/0 pin (connection for X2)
Pin
Assignment
1 L1 out
2 N
1)
3 L3 out
4 Brake L1 (switched)
1)
5 Temperature sensor
6 Brake L3 (direct)
1)
7 L2 out
8 Temperature sensor
PE (yellow/green)
1)
See brake variants