General Operation
7.12 Trends
SITRANS LUT400
Operating Instructions, 07/2019, A5E33329501-AC
151
7.12 Trends
To view trend lines, navigate to Maintenance and Diagnostics (3.) (Page 239) > Diagnostics
(3.2.) (Page 241) > Trend (3.2.2.) (Page 242). The PV (in percentage) is logged at five
minute intervals and trend displays up to 3000 data points since last power up.
Press RIGHT arrow to request a trend.
Cross-hairs
Current measurement
Pan left/right icon
Zoom icon
Exit icon
Use UP or DOWN arrow to scroll to an icon. When an icon is highlighted, that
feature becomes active.
To move the cross-hair, press RIGHT arrow to increase the value, LEFT arrow to
decrease.
To Zoom into an area, position the cross-hairs at the center of that area, select Zoom
icon, and press
RIGHT arrow . Press LEFT arrow to Zoom out.
To return to the previous menu, select Exit icon then press RIGHT arrow .
Note
When a fail-safe condition has occurred, it will appear as a gap in the Trend line.
Trend view will not timeout. This view will display on LUI until the exit icon is selected.