9.2.16.1 Daily Totalizer (2.16.1.)
Read only. Current daily totalizer value. (Automatically resets daily and can be reset by
user.)
Values
Range: 0.00 to 999999999
Default: 0.00
9.2.16.2 Running Totalizer (2.16.2.)
Read only. Current running totalizer value. (Reset only by user.)
Values
Range:
0.00
to
999999999
Default: 0.00
9.2.16.3 Totalizer Decimal Position (2.16.3.)
Sets the maximum number of decimal places to be displayed.
Options
NO DIGITS
no digits after the decimal point
1 DIGIT
1 digit after the decimal point
*
2 DIGITS
2 digit after the decimal point
3 DIGITS
3 digit after the decimal point
9.2.16.4 Totalizer Multiplier (2.16.4.)
Use this feature if the LCD Total increments by an amount that is too large (or too small)..
Options
.001
.01
.1
*
1
10
100
1000
10,000
100,000
1,000,000
10,000,000
Enter the factor (powers of 10 only) by which actual flow is divided, prior to display on LCD.
Use a value such that the eight-digit totalizer doesn’t roll over between readings.
Example: For an LCD Total display in 1000s of flow units, enter 1000.